Automatic Upper Arm Blood Pressure Monitor U81D

Automatic Upper Arm Blood Pressure Monitor U81D

Short Description:

● CE&FDA certificate
● OEM&ODM available
● LCD digital display
● Oscillometric method
● A portable electronic blood pressure monitor


Product Detail

Product Tags

Description Automatic upper arm blood pressure monitor U81D
Display LCD digital display
Measuring principle Oscillometric method
Measuring localization Upper arm
Measurement range Pressure 0~299 mmHg
  Pulse 40~199 pulses/min
Accuracy Pressure ±3mmHg
  Pulse ±5% of reading
LCD indication Pressure 3 digits display of mmHg
  Pulse 3 digits display
  Symbol Memory/Heartbeat/Low battery
Memory function 2x90 sets memory of measurement values
Power source 4pcs AAA alkaline battery / type-c 5 V
Automatic power off In 3 minutes
Main unit weight Approx.230g (batteries not included)
Main unit size LX W X H=124X 95X 52mm4.88X 3.74X 2.05 inch
Main unit lifetime 10,000 times under normal use
Battery life Could be used for 300 times for normal condition
Accessories Cuff, instruction manual
Operating environment Temperature 5~40°C
  Humidity 15% ~ 93%RH
  Air pressure 86kPa ~ 106kPa
Storage environment

 

Air pressure

86kPa ~ 106kPa

Temperature -20°C - 55°C, Humidity: 10% ~ 93%

avoid crash, sun burn or rain during transportation.

Expected service life 5 years

Using Caution

For accurate measurements, please do as the following steps:

1.Relax about 5-10 minutes before measuring. Avoid eating, drinking alcohol, smoking, and bathing for 30 minutes before taking measurements.
2.Roll up your sleeve but not too tight, remove watch or other ornaments from the measured arm;
3.Put the upper arm blood pressure monitor on your left wrist,and the led screen up towards the face.
4.Please sit on a chair and take an erect body posture, make sure the blood pressure monitor is on the same level with heart. Don't bend over or cross your legs or talking during the measurement, until measurement is complete;
5.Read the measuring data and check your blood pressure by referring the WHO classification indicator .
 
NOTE: Arm circumference should be measured with measuring tape in the middle of the relaxed upper arm. Do not force cuff connection into the opening. Make sure the cuff connection is not pushed into the AC adapter port.
 
How to set the users?
Press S button when power off, the screen will display user 1/user 2, press M button to switch from user1 to user2 or user2 to user1, then press S button to confirm the user.

How to set the year/month/ date time?
Continue to above step, it will enter into year setting and the screen will flash 20xx. Press M button to adjust the number from 2001 to 2099, then press S button to confirm and enter into the next setting. The other settings are operated like year setting.

How to read memory records?
Please press the M button when power off, the latest 3 times average value will be shown. Press M again to show the latest memory, press S button to show the oldest memory, as well as subsequent measurements can be shown one after the other by pressing the M button and S button each time.